Description
Fieldpiece DRX3 Refrigerant and Combustible Gas Leak Detector
Your all-in-one problem solver — Find leaks FAST
Travel light with one tool, one sensor, that quickly and accurately detects HC, HFC, HCFC, CFC, HFO, H2/N2 (Tracer Gas) and blend refrigerants, as well as heating gases. The DRX3 is designed for performance and safety, complying with ATEX Zone 2 and Class I, division 2 hazardous location requirements. The lightweight, rugged DRX3 helps you locate system leaks quickly with multiple visual and audio feedback indicators that change with leak intensity: Flashing LED at probe tip, Loud audible alarm, Graphical and numerical display, and Live in the Job Link System App. Lighten your toolbag with the all-in-one DRX3 leak detector.
Key Features & Benefits
- Detects A3, A2L, A1 refrigerants including HC, HFC, HCFC, CFC, HFO, H2/N2 (Tracer Gas) and blend refrigerants
- Also detects Natural gas, Propane, Butane, and Methane combustible gases.
- Accurate and field-replaceable, heated diode sensor
- Long-life, field-replaceable batteries
- Auto and manual zero modes
- High, medium and low sensitivity settings
- Job Link® System App connected
- Flashing LED at probe tip
- Loud, audible alarm
- Graphical and numerical display
Specs
Fieldpiece DRX3 Leak Detector Specs | |
---|---|
Sensor Type | Heated diode |
Sensor Life | 300 hours typical |
Sensitivity Levels | High, Medium, Low (selectable) |
Maximum Sensitivity | 1g/yr (0.03 oz/yr), stationary; 3g/yr (0.1 oz/yr), in motion |
Detection Feedback | Flashing LED, LCD bar graph and digits, audible beep, Job Link® app |
Refrigerants | HC, HFC, HCFC, CFC, HFO, H2/N2 (Tracer Gas: 5% Hydrogen, 95% Nitrogen), and blends |
Heating Gases | Natural Gas, Propane, Butane, Methane |
For Use With | A3 (R-290, R-600a, R-600, R-50, R-1270), A2L (Including R-32, R-454B, R-1234yf), and A1 refrigerants |
Not For Use With | R-702, R-717, R-744 |
Safety Compliance | ATEX Zone 2(II 3 G Ex ic IIA T2 Gc); Class I, Division 2, Group D, T2 Hazardous Locations |
Operating Environment | -4°F to 122°F (-20°C to 50°C); < 95% RH (non-condensing) |
Battery Type | 4x Replaceable AA Lithium Iron Disulfide (To maintain ATEX and CID2 compliance, use 4x Energizer L91 AA batteries.) |
Battery Capacity | 1.5 VDC (nominal) 3500 mAh |
Battery Life | 60 hours typical |
Auto Power Off | 10 minutes without detection or button press |
Radio Frequency | 2.4 GHz |
Wireless Range | Up to 656 feet (200 meters) line of sight |
Storage Temperature | -4°F to 140°F (-20°C to 60°C); < 95% RH |
Weight | 15.6 oz (442g) with Batteries Installed |
Water Resistance | IP54 Main Body |
Includes
- (1) Fieldpiece DRX3 Refrigerant and Combustible Gas Leak Detector
- (1) Heated Diode Sensor RXA3
- (1) Blow Molded Case