Descripción
Fieldpiece SC680 True RMS Electrical Clamp Meter with Swivel Head, 600AC/DC
Direct integration with Job Link System App!
Whether you're working on small circuitry in mini-splits or large commercial equipment, the SC680 delivers the electrical measurements HVAC/R technicians need for installation, service, and troubleshooting. It connects directly to the Job Link System app for wireless measurement logging, measures power consumption (W/kW) to help evaluate system performance, verifies 3-phase rotation with two leads, captures True RMS VAC and AAC readings, and uses a Low Pass Filter (LPF) to improve accuracy on VFD systems.
Características y ventajas principales
- Measures power (W/kW) to track system energy consumption
- Lecturas de valor eficaz verdadero (TRMS) a través de la pinza o los cables de medición
- Low Pass Filter (LPF) helps improve voltage and frequency readings on VFD systems
- Mide la corriente de arranque con la función InRush
- Precisión de tensión adecuada para su uso en variadores de frecuencia (VFD)
- Indica rotación trifásica con dos cables; no es necesario llevar un cable adicional
- Mide los condensadores de arranque y de funcionamiento
- Imán para fijar el medidor durante su uso
- Comprueba diodos y resistencias de hasta 50 megaohmios
- Cables con conector Molex para conectores de alimentación pequeños
- Clasificación de seguridad CAT IV-600 V/CAT III-1000 V
- Amperios de corriente continua y diodos para inversores de sistemas mini-split
- Temperatura dual para delta T
- Rotating swivel clamp head for easy viewing at any angle
- Open the clamp and an LED worklight comes on to help spot the bundle you are hunting
- Tamaño compacto para trabajar en espacios reducidos, como las placas de mini-split
- Almacenamiento de cables de prueba
- Esfera retroiluminada
Direct Integration with Job Link System App!
Pair all your Job Link tools in the Job Link App to receive and document a complete system snapshot wirelessly. From the new SC480 and SC680 clamp meters and SM382V and SM482V manifolds, to the JL3 Job Link Probes, and SRS3 scale, all measurements are live and in real time so you can see exactly how adjustments are affecting the system.
Document all Measurements
Clearly communicate the health of the system with your co-workers and customers. Proven to help reduce call backs and increase sales.
- Wireless direct to the Job Link System mobile app
- Up to 1000 feet (305m) line of sight. Distance decreases through obstructions.
- Document electrical measurements
- Calculate power and system efficiency
- Measure accurate blower amperages behind the door
- Wireless monitoring of compressor VAC and AAC
Características técnicas
| Volts AC (VAC) True RMS (50-400Hz) | |
|---|---|
| Ranges: | 1000mV, 10V, 100V, 750V |
| Resolución: | 0.1mV |
| Precisión: |
±(1.5% + 10) 50Hz to 60Hz ±(2.0% + 10) 60Hz to 400Hz Unspecified at 400Hz and greater |
| Volts DC (VDC) | |
| Ranges: | 1000mV, 10V, 100V, 1000V |
| Resolución: | 0.1mV |
| Precisión: | ±(0.5% + 5) |
| Amps AC (AAC) True RMS (50-60Hz) | |
| Ranges: | 100A, 600A |
| Resolución: | 0.01A |
| Precisión: |
±(2.5% + 15) 100A ±(2.0% + 10) 600A |
| Frequency (Hz) Through Clamp | |
| Ranges: | 10Hz to 400Hz |
| Resolución: | 0.1Hz |
| Precisión: | ±(0.1% + 5) |
| Amps DC (ADC) | |
| Ranges: | 100A, 600A |
| Resolución: | 0.01A |
| Precisión: |
±(2.5% + 15) 100A ±(2.0% + 10) 600A |
| MicroAmps DC (µADC) | |
| Ranges: | 1000µA |
| Resolución: | 0.1µA |
| Precisión: | ±(1.0% + 5) |
| Frequency (Hz) Through Leads | |
| Ranges: | 100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz |
| Resolución: | 0.01Hz |
| Precisión: | ±(0.1% + 5) |
| Duty Cycle (%) | |
| Ranges: |
5%-95% (40Hz to 1kHz) 10%-90% (1kHz to 10kHz) 20%-80% (10kHz to 20kHz) |
| Resolución: | 0.1% |
| Precisión: | ±(2% + 10) |
| Capacitance (MFD) | |
| Ranges: | 10nF, 100nF, 1000nF, 10µF, 100µF, 1000µF, 10mF |
| Resolución: | 0.01nF |
| Precisión: | ±(3% + 15) 10nF, ±(3% + 5) 100nF to 1000µF, ±(5% + 5) 10mF |
| Resistance (Ω) | |
| Ranges: | 100Ω, 1000Ω, 10kΩ, 100kΩ, 1000kΩ, 10MΩ, 50MΩ |
| Resolución: | 0.01Ω |
| Precisión: | ±(1.0% + 15) 100Ω, ±(1.0% + 5) 1000Ω to 100kΩ, ±(1.5% + 5) 1000kΩ, ±(3.0% + 5) 10MΩ to 50MΩ |
| Continuity | |
| Ranges: | 100Ω |
| Resolución: | 0.01Ω |
| Response time: | 100ms |
| Diode Test | |
| Test current: | 0.8mA (Approx.) |
| Open circuit volts: | 3.2VDC typical |
| Precisión: | ±(1.5% + 5) |
| Dual Temperature (T1, T2, T1-T2) | |
| Ranges: | -58°F to 2372°F, (-50°C to 1300°C) |
| Resolución: | 0.1° |
| Precisión: |
±(1°F) 32°F to 120°F, ±(1°C) 0°C to 49°C ±(1%+2°F) 32°F to 932°F, ±(1%+1°C) 0°C to 500°C ±(2%+6°F) -58°F to 32°F, ±(2%+3°C) -50°C to 0°C ±(2%+6°F) 932°F to 2372°F, ±(2%+3°C) 500°C to 1300°C |
| Phase Rotation Test (L1L2, L1L3) | |
| Ranges: | 80±5 VAC to 600VAC (50Hz to 80Hz) |
| Resolución: | 0.1V |
| Precisión: | ±(1.5% rdg + 10 dgts) |
Incluye
- (1) Pinza amperimétrica SC680
- (1) RCT2 Molex Probe Tips
- (1) ADLS2 Silicone Leads
- (1) ASA2 Gator Clip Leads
- (2) ATB1 Type K Thermocouples
- (2) Velcro Straps
- (1) 9V Alkaline Battery
- (1) ANC7 Protective Padded Case