Descripción
Fieldpiece SMAN440 Wireless Digital Manifold with Hilmor 72" Ball Valve 4-Hose Pack
Right on Target with Live Measurements
Características principales:
- Wireless Advantage **
- 4 Ports for One Time Hook-Up
- Display Designed for HVACR
- Reliable Regardless of Elevation
The Fieldpiece SMAN440 is a 4-port, wireless digital manifold with a large 3/8" port for faster evacuations and recovery. With four ports, HVACR professionals can now evacuate a system, pull a vacuum, add refrigerant and dial in the charge at one time, without having to hook and unhook any hoses.
It can also wirelessly send six measurements (indoor wet bulb, outdoor dry bulb, suction line temperature, suction line pressure, liquid line temperature, and liquid line pressure) to the Fieldpiece HVAC Guide System Analyzer, model HG3. The HG3 then combines the SMAN440 wireless measurements with wireless airflow measurements for full system analysis.
** The manifold can both send and receive wireless measurements to a JL2 wireless transmitter link so HVACR professionals get a live view of the system and how it's operating. Measurements are updated in real-time while conditions are changing, and while adjustments are being made. So technicians know their work is the most accurate it can be. A JL2 Wireless transmitter link allows you to take data wirelessly from several FieldPiece products (including this SMAN440) and be the relay point to deliver it to an APP in your smart device (eg smart phone or tablet). More info on the JL2 is here: www.trutechtools.com/JL2
Características principales:
- Measures:
- 2 Pressures
- 2 Temperatures
- Vacuum in Microns
- Calculates:
- Sobrecalentamiento
- Subenfriamiento
- Target Superheat
- Vapor Saturation
- Liquid Saturation
- Displays Pressures, Superheat, Subcooling, Pipe Temps, Saturation Temperatures, and Refrigerant Type all on one screen.
- Loaded with 45 refrigerants and the capability of adding more through future firmware updates.
- Sturdy Plastic Casing
- Improved valves are easier to open and close and create a stronger seal.
- Highly durable LCD for clear and accurate measurements.
- Highly Accelerated Life Tested
Características técnicas
- Mini-USB port: For updating to newer versions of firmware
- Display size: 5 inches (diagonal)
- Backlight: Blue (On for 3 minute unless turned off manually)
- Battery: 6 x AA (Battery life below based on alkaline type)
- Battery life: 350 hours (without backlight and wireless)
- Low battery indication: is displayed when the battery voltage drops below the operating level
- Auto shut off: 30 minutes of inactivity when APO is activated
- Over range: "OL" or "-OL" is displayed
- Operating environment: 32°F to 122°F (0°C to 50°C) at <75% RH
- Temperature coefficient: 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C), per 0.6°F (32°F to 64°F, 82°F to 122°F
- Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed)
- Weight: 4.03 lbs (1.83 kg)
Presión
- Sensor type: Absolute pressure sensors
- Connector type: Standard 1/4" and 3/8" NPT male flare fitting
- Range: 29” HgV to 580psig (English), 74 cmHgV to 0 to 4000KPa (Metric), 4.000MPa (Metric), and 40.00bar (Metric)
- Resolution: 0.1 psi/inHg; 1 kPa/cmHg; 0.001MPa; 0.01bar
- Accuracy: 29” HgV to 0” HgV: ±0.2” HgV 74 cmHgV to 0 cmHgV: ±1 cmHgV 0 to 200 Psig: ±1 Psi; 0 to 1378 KPa: ±7 KPa; 0 to 1.378MPa: ±0.007MPa; 0 to 13.78 bar ±0.07 bar 200 to 580 Psig: ±(0.3% of reading+1 Psig); 1378 to 4000KPa: ±(0.3% of reading+7 Kpa); 1.378 to 4.000MPa: ±(0.3% of reading+0.007MPa); 13.78 to 40.00bar: ±(0.3% of reading +0.07bar)
- Maximum overload pressure: 800 psig
- Units: Psig, kPa, MPa, bar, inHg, and cmHg
Temperatura
- Sensor type: Type K thermocouple
- Range: -95°F to 999.9°F (-70°C to 537.0°C)
- Resolution: 0.1°F/°C
- Accuracy: ±(1.0°F) -95°F to 199.9°F; ±(0.5°C) -70°C to 93°C ±(2.0°F) 200°F to 999.9°F; ±(1.0°C) 93°C to 537.0°C Note: All accuracies are after a field calibration.
Wireless
- Wireless range: 1 to 100 feet (30m)
- Initial sync setup range: 1 to 10 feet Wirelessly transmit to Fieldpiece HVAC Guide® HG3 System Analyzer Wirelessly receive indoor wet bulb (IDWB) and outdoor dry bulb (ODDB) from Fieldpiece transmitters
Refrigerantes
The P-T charts of the following 45 refrigerants come pre-programmed into your SMAN. In your SMAN the refrigerants are listed in order of most commonly used. Here, they are listed in numerical order for easy reference.
R11, R113, R114, R12, R123, R1234YF, R124, R125, R13, R134A, R22, R23, R32, R401A(MP39), R401B, R402A, R402B, R404A, R406A, R407A, R407C, R407F, R408A, R409A, R410A, R414B (Hotshot), R416A, R417A, R417C (HOT SHOT 2), R420A, R421A, R421B, R422A, R422B(NU22B), R422C(Oneshot), R422D, R424A, R427A, R434A(RS-45), R438A(MO99), R500, R502, R503, R507A, R508B (Suva95)
Using Different Refrigerants
You can use your manifold with different refrigerants. Be sure to purge your manifold and hoses before connecting to a system with a different refrigerant.
Incluye
- 4-port Digital Manifold - SMAN440
- 2 Type-K Pipe Clamp Thermocouples - TC24
- Padded Carrying Case - ANC10
- 6 AA Batteries
- Hilmor 1839143 Refrigeration Hoses with Ball Valve Adapters
Vídeos
Software / Aplicación