null

Download the TruTech Tools App!

Faster ordering, easier tracking, and be the first to know about exclusive offers. 90+ brands in your pocket. Learn More

UEi 522KIT Oil Burner & Boiler Install Kit with C161 Combustion Analyzer, Clamp Meter, Manometer, Leak Detector, Thermometer, and Smoke Test Kit

Referencia:
522KIT
MPN:
522KIT
  • UEi 522KIT Oil Burner & Boiler Install Kit with C161 Combustion Analyzer, Clamp Meter, Manometer, Leak Detector, Thermometer, and Smoke Test Kit
  • UEi 522KIT Oil Burner & Boiler Install Kit with C161 Combustion Analyzer, Clamp Meter, Manometer, Leak Detector, Thermometer, and Smoke Test Kit
  • UEi 522KIT Oil Burner & Boiler Install Kit with C161 Combustion Analyzer, Clamp Meter, Manometer, Leak Detector, Thermometer, and Smoke Test Kit
  • UEi 522KIT Oil Burner & Boiler Install Kit with C161 Combustion Analyzer, Clamp Meter, Manometer, Leak Detector, Thermometer, and Smoke Test Kit
MSRP: $1,779.70
Price: $1,512.75
— You save $266.95

Descripción

UEi KANE 522KIT Oil Burner & Boiler Install Kit with C161 Combustion Analyzer, Clamp Meter, Manometer, Leak Detector, Thermometer, and Smoke Test Kit

Featuring the C161, DL579, EM201B, CD100A, and PDT655.

This Kit provides the recommended test instruments required by Oil Burner & Boiler start up manuals for proper installation and maintenance. Most equipment warranties require initial install readings to be documented upon installation.The 522KIT is packed in a UEi Tool Backpack. Built rugged, waterproof base, two compartments with inner pocket options and includes D-clip.

This Kits helps confirm:

  • Manufacturer requirements to maintain warranty
  • Combustion analysis for fuel efficiency
  • Heat exchanger integrity
  • Smoke level in the flue gases
  • CFM via external static pressure test
  • Gas flow pressure
  • System is safe from gas leaks
  • Proper high voltage to power supply and ground
  • Low voltage meets wiring diagram requirements

UEI C161 Residential Combustion Analyzer

No te pierdas las fantásticas ventajas de UEi Service+.
Registra tu analizador de combustión en UEi y recibe una notificación cuando llegue el momento de renovarlo.

Backed by UEi Service+ to allow up to 10 years' warranty, same day recertification and a reduced cost of ownership. The C161 Residential Combustion Analyzer is easy to use with a rugged design, multiple sensor protections and altitude compensation. Prints to optional printer. Essential information for the installation and maintenance of furnaces and boilers.

El C161 cuenta con dos tipos de protección de sensores: un sensor de CO con filtro de NOx y un sistema de detección de bajo caudal. Además, incorpora una tecnología de sensores que reduce el coste de mantenimiento, una prueba del intercambiador de calor para comprobar su integridad y la temperatura diferencial. El C161 incluye compensación de altitud para mantener lecturas precisas a cualquier altitud, apagado automático por purga y 8 combustibles preprogramados, entre los que se incluyen el gas natural y el propano.

The C161 has a 6-Line display to view readings on one screen, which is a favorite among technicians. The DMM Style dial makes it easy to select the test needed. It also features a water trap to protect the sensor with a check light to remind to look for condensate built-up, a magnetic boot for hands-free operations, and an IR printer port to print to an optional printer sold separately, making it easy to document test results for later analysis.

Características y funciones del producto:

  • Hasta 6 años de garantía con recertificación anual
  • 2 Tipos de protección de sensores
  • NOx filtrado
  • Entradas de temperatura de tipo K
  • Detección de bajo caudal
  • Diferencial de temperatura
  • Pantalla retroiluminada de 6 líneas
  • 8 combustibles preprogramados
  • Tiempo de arranque de 30 segundos
  • Compensación por altitud elevada
  • 30 posiciones de memoria
  • Trampa de agua de protección
  • Purga automática de aire fresco
  • Soporte magnético
  • Conexión para impresora IR (impresora no incluida)


UEi DL579 True RMS Clamp Meter with Temperature and Capacitance

True-RMS Dual Display 600A HVAC/R Clamp Meter w/ Temperature & Capacitance


Application
Measure capacitance, voltage, circuit continuity, resistance, temperature via K-Type thermocouples and diode malfunctions. Check system boards and live wires.

Functions:
TRMS:
AC Volts: 750VAC
DC Volts: 1000VDC
AC current (amps): 600A AC
AC micro current (amps): 2000µA
DC micro current (amps) 2000µA
DC micro volts: 600mV
AC micro volts: 600mV
Resistance (Ohms): 60MΩ
Capacitance (Farads): 6000µF
Frequency (Hertz): 99.99kHz
Duty cycle: 1.0 to 99.0%
Temperature: -328° to 2462°F
Continuity:
Diode:
NCV Detection:
LRA Inrush:
Low Z:
Características:
Hold:
Min/Max:
Ranging: Auto/Manual
Auto power off:
Display count: 6000
Low battery warning:
Backlight:
Dual display:
Temperature Inputs: K-Type
Protective boot or overmolding:
Magnetic mount: Optional
Warranty: 1 Year limited
Audible and visual alerts:
K-type input:
Digital:

UEi CD100A Combustible Gas Leak Detector

Find Combustible Gas Leaks Quickly!

The CD100A is the perfect serviceman's tool designed to detect combustible gas leaks in residential and small commercial applications. Semiconductor sensor responds instantaneously to all combustible gases. The easily adjusted, steady tic rate can be used in tight quarters where others might not fit.

  • Easy one hand operation
  • Simple adjustable tic rate
  • Long 18" gooseneck
  • Tip light in sensor cover illuminates the area of the leak
  • Headphone jack

UEi EM201B Dual Input Differential Manometer

A Digital, Time Saving Alternative to U-Tube Pressure Measurement.

  • EM201B (Dual input) Measures ±60 inches water column .001 wg resolution below 9.999”
  • Ruggedized with sturdy metal fittings
  • Rubber-boot with built-in magnet
  • Measures in inches water column, mBar, PSI, and Pa (auto range to hPa)
  • Dynamic Min/Max value capture
  • Data hold
  • Apagado automático
  • Back-lit display
  • Three year limited warranty

Termómetro de bolsillo plegable UEi PDT655 con pantalla grande y de fácil lectura

Termómetro de bolsillo plegable con pantalla grande y de fácil lectura

Características:

  • Rango: de -58 °F a 572 °F (de -50 °C a 300 °C)
  • Diferencia de temperatura
  • Apagado automático
  • Retroiluminación
  • Soporte magnético
  • Sonda plegable

UEI Smoke Pump Test Kit

  • High impact barrel
  • Stainless steel hardware
  • Fits all types of smoke paper
  • 1 Year limited warranty

Características técnicas

C161 Specs

Medición de la temperatura
Parámetro Gama Resolución Precisión
Temperatura de los gases de combustión De 32° a 1112°F (de 0° a 600°) 0,1 °F (0,1 °C) ±0,5 °F (0,5 °C)
Temperatura de entrada (sensor interno) 0,1 °F (0,1 °C) ±1 °F (1 °C)
Temperatura de entrada (sensor externo) De 32° a 1112°F (de 0° a 600°) 0,1 °F (0,1 °C) ±0,5 °F (0,5 °C)
Medición de gases de combustión
Parámetro Gama Resolución Precisión
Monóxido de carbono De 0 a 2000 ppm 1 ppm ±3 ppm o ±5 % de la lectura
(el valor que sea mayor)
(Opcional: H2 compensado (si procede)) De 2.000 a 10.000 ppm 1 ppm ±10 % de la lectura
Dióxido de carbono Del 0 al 20 % 0.1% ±0,3 % en volumen
Cálculos
Parámetro Gama Resolución Precisión
Oxígeno Del 0 al 21 % 0.1% ±0,3 % en volumen
Rendimiento (neto o bruto) Del 0 al 99,9 % 0.1% ±1 % de la lectura
Alta eficiencia (C) Del 0 al 119,9 % 0.1% ±1 % de la lectura
Exceso de aire Del 0 al 119,9 % 0.1% ±0,2 % de la lectura
Relación CO/CO₂ De 0 a 0,9999 0.0001 ±5 % de la lectura
General
Combustibles preprogramados Pellets, gasóleo ligero, GLP, butano, propano, gas natural, bioaceite, gasóleo pesado
Duración de la batería >8 horas (de forma continua con la bomba encendida)
Certificación La serie C160 ha sido sometida a pruebas por TÜV y cuenta con la certificación EN 50379, partes 1 a 3, de conformidad con la Primera Ordenanza Federal Alemana sobre Control de Emisiones (BimSchV).
Temperatura de funcionamiento De 32° a 113°F (de 0° a 45°C)
Humedad de funcionamiento Del 15 % al 90 % de humedad relativa.
Fuente de alimentación Baterías recargables, carga por USB
Dimensiones 8,54" x 4,18" x 1,86"
Peso 1 libra y 5,1 onzas.

DL579 Specs

AC Amps Measurement - Jaw input
Gama Resolución Precisión Overload Protection
60.00A 0.01A ±2.0% +8dgts 600V RMS
600.0A 0.1A
Minimum Current for Clamp Measurement: 0.3A
DC Microamps Measurement - Test lead input
Gama Resolución Precisión Overload Protection
600.00µA 0.1µA ±1.2% +3dgts 600V RMS
2000µA 1µA
AC Microamps Measurement -Test lead input
Gama Resolución Precisión Overload Protection
600.0µA 0.1µA ±2.0% +5dgts 600V RMS
2000µA 1µA
45Hz to 400Hz True RMS
DC Volts Measurement
Gama Resolución Precisión Overload Protection
600.0mV 0.1mV ±0.5% +4dgts 1000V RMS
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
1000V 1V ±0.8% +10dgts
AC Volts Measurement
Gama Resolución Precisión Overload Protection
600.0mV 0.1mV ±2.0% +5dgts 750V RMS
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
750V 1V
45Hz to 400Hz True RMS
Ohms Measurement
Gama Resolución Precisión Overload Protection
600.0Ω 0.1Ω ±1.0% +4dgts 600V RMS
6.000kΩ 0.001kΩ
60.00kΩ 0.01kΩ
600.0kΩ 0.1kΩ
6.000MΩ 0.001MΩ
60.00MΩ 0.01MΩ ±2.0% +4dgts
Diode Test
Gama Open Circuit Voltage Test Current (Typical) Overload Protection
6.0V < 3.0V DC 0.25mA 600V RMS
Capacitance Measurement
Gama Resolución Precisión Overload Protection
60.00nF 0.01nF 3.5% +6dgts 600V RMS
600.0nF 0.1nF
6.000µF 0.001µF
60.00µF 0.01µF
600.0µF 0.1µF
6000µF 1µF
Medición de la temperatura
Gama Resolución Precisión Overload Protection
-328° to 999°F 0.1°F ±(1.0% +3.6°F) 30V RMS
-200° to 999°C 0.1°C ±(1.0% +2.0°C)
1000° to 2462°F 1°F ±(1.0% +3°F)
1000° to 1350°C 1°C ±(1.0% +2°C)
Frequency Measurement - Test lead input
Gama Resolución Precisión Overload Protection
99.99Hz 0.01Hz 0.1% +4dgts 1000V RMS
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99kHz 0.01kHz
Minimum Frequency: 0.5Hz, Sensitivity: > 10% of each AC volt range except 4V (>20%) range only
Ciclo de trabajo
Gama Precisión Overload Protection
1.0 to 99.0% ±(0.2% per kHz +0.1% +5 dgts) 1000V RMS
Audible Continuity Measurement
Open Circuit Voltage < 0.64V Overload Protection
Threshold Approx : < 40Ω 600V RMS

EM201B Specs

Rango de medición -40" to +40" WG
-100 to +100 mBar
Precisión ±0.02"WG < 2"WG
±1%RDG > 2"WG
Resolución 0.001" -9.999" to +9.999" WG
0.01" for < -10" or > +10" WG
Operating Range 32° -104°F (0° - 40°C)
10 - 90% RH non condensing
Duración de la batería 40 hours min with alkaline battery

Incluye

  • (1) Analizador de gases de combustión UEI C161
  • (1) Sonda para conductos de humos con cono y manguera
  • (3) Pilas recargables AA
  • (1) Cable de carga USB
  • (1) Guía de inicio rápido
  • (1) UEi DL579 Clamp Meter 400Amps
  • (1) Test Leads (ATL55)
  • (2) Temp Probe (ATT29)
  • (1) Alligator Clips (AAC3)
  • (2) Batteries (AAA)
  • (1) Zippered Pouch
  • (1) Manual
  • (1) Dual Input Electronic Manometer (EM201B)
  • (2) Magnetic static pressure tips (ASP1)
  • (2) Brass valve fitting connector (BF100)
  • (1) Soft carrying case (AC319)
  • (1) Pressure tubing
  • (1) Pila de 9 V
  • (1) CD100A Combustible Gas Leak Detector
  • (1) 9V Batter
  • (1) Termómetro de bolsillo plegable diferencial UEi PDT655
  • (1) Smoke Pump Test Kit with Chart
  • (10) Smoke Test Paper