Descripción
Fluke 1503 Insulation Resistance Tester, 500V/1000V Test Voltages
Handles all the basic insulation testing needs
The Fluke 1503 Insulation Resistance Tester delivers the essential testing capabilities electricians need to verify insulation integrity, troubleshoot wiring systems, and help maintain safe electrical installations. Designed for residential, commercial, and light industrial applications, this rugged handheld meter performs insulation resistance testing up to 2000 MΩ with selectable 500V and 1000V test voltages. Built on Fluke's trusted platform, the 1503 combines dependable performance, simple operation, and a compact design that's easy to carry from job to job, making it a practical choice for everyday insulation testing and preventive maintenance.
Características y ventajas principales
- A rugged, compact insulation resistance tester for residential and commercial electricians
- Performs insulation tests from 0.01 MΩ to 2000 MΩ
- Offers two insulation test voltages: 500 V and 1000 V
- Measures resistance from 0.01 Ω to 20.00 kΩ
- Measures AC/DC voltage from 0.1 V to 600 V
- Includes auto-discharge of capacitive voltage for added user protection
- Provides lo-ohms earth-bond continuity (200 mA)
- Simplifies repetitive or hard-to-reach testing with the remote test probe
- Saves battery power with auto power off
- Presents results on a large, backlit display
- Features CAT IV 600 V overvoltage category rating
- Comes with remote probe, test leads, test probes, alligator clips, and one-year warranty
- Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
- Runs on four AA alkaline batteries (NEDA 15A or IEC LR6) for at least 1,000 insulation tests
Características técnicas
| Fluke 1503 Insulation Resistance Meter Specs | |
|---|---|
| AC/DC Voltage Measurement | |
| Gama | 600.0 V |
| Resolución | 0.1 V |
| Accuracy, 50 Hz to 400 Hz | ±(2% of Reading + 3 Digits) |
| Input Impedance | 3 MΩ nominal, <100 pF |
| Common Mode Rejection Ratio | >60 dB at DC, 50 Hz, or 60 Hz with 1 kΩ unbalanced |
| Overload Protection | 600 V RMS or DC |
| Earth-Bond Resistance Measurement | |
| Range and Resolution |
20.00 Ω at 0.01 Ω 200.0 Ω at 0.1 Ω 2,000 Ω at 1.0 Ω 20.00 kΩ at 0.01 kΩ |
| Precisión | ±(1.5% + 3 Digits) |
| Overload Protection | 2 V RMS or DC |
| Open-Circuit Test Voltage | >4.0 V, <8 V |
| Short-Circuit Current | >200.0 mA |
| Insulation Measurement | |
| Rango de medición | 0.01 MΩ to 2,000 MΩ |
| Test Voltages | 500 V and 1,000 V |
| Test Voltage Accuracy | +20%, -0% |
| Short-Circuit Current | 1 mA nominal |
| Auto Discharge | Discharge time under 0.5 second for capacitance of 1 µF or less |
| Live-Circuit Indicator | Inhibits testing if terminal voltage is greater than 30 V before test initialization |
| Maximum Capacitive Load | Operable with loads up to 1 µF |
| Measurement Accuracy at 500 V | ±(1.5% + 5 Digits) |
| Measurement Accuracy at 1,000 V | ±(1.5% + 5 Digits) to 2,000 MΩ; ±(10% + 3 Digits) above 2,000 MΩ |
| Especificaciones generales | |
| Maximum Voltage Applied to Any Terminal | 600 V AC RMS or DC |
| Temperatura de almacenamiento | -40°C to 60°C (-40°F to 140°F) |
| Temperatura de funcionamiento | -20°C to 55°C (-4°F to 131°F) |
| Temperature Coefficient | 0.05 x specified accuracy per °C at temperatures below 18°C or above 28°C (below 64°F or above 82°F) |
| Relative Humidity |
0% to 95% at 10°C to 30°C (50°F to 86°F) 0% to 75% at 30°C to 40°C (86°F to 104°F) 0% to 40% at 40°C to 55°C (104°F to 131°F) |
| Vibration | Random, 2 g, 5 Hz to 500 Hz per MIL-PRF-28800F, Class 2 instrument |
| Shock Resistance | 1 m drop per IEC 61010-1, 2nd Edition; six sides on an oak floor |
| Electromagnetic Compatibility | In an RF field of 3 V/m, accuracy equals specified accuracy per EN 61326-1:1997 |
| Safety Rating | CAT IV 600 V |
| Safety Compliance | ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No. 61010-1-04, and IEC/EN 61010-1, 2nd Edition |
| Certifications | CSA per CSA/CAN C22.2 No. 61010.1-04; TUV per IEC/EN 61010-1, 2nd Edition |
| Batteries | Four AA alkaline batteries (NEDA 15A or IEC LR6) |
| Battery Life - Insulation Testing | At least 1,000 tests at 1,000 V into 1 MΩ, with 5 seconds on and 25 seconds off |
| Battery Life - Resistance Measurement | At least 2,500 earth-bond resistance measurements at 1 Ω, with 5 seconds on and 25 seconds off |
| Dimensions (H x W x L) | 1.97 x 3.94 x 8.00 in (5.0 x 10.0 x 20.3 cm) |
| Peso | 1.2 lb (550 g) |
| IP Rating | IP40 |
| Operating Altitude | 2,000 m at CAT IV 600 V; 3,000 m at CAT III 600 V |
| Storage Altitude | 12,000 m |
| Over-Range Capability | 110% of range |
| Accesorios incluidos | TL224 Test Leads, TP74 Test Probes, red and black alligator clips, holster, and remote probe |
Incluye
- (1) Fluke 1503 Insulation Resistance Tester
- (1) Remote Probe
- (1) TL224 Test Leads
- (1) TP74 Test Probes
- (1) Alligator Clips
- (1) Holster