Description
Hilmor 1950536 Brushless DC Refrigerant Recovery Machine
The testo 830-T4 infrared thermometer also achieves accurate results at greater distances during non-contact surface temperature measurement. This is provided by its 30:1 optics and powerful processor. The infrared temperature measuring instrument carries out measuring tasks in trade and industry quickly and efficiently.
Features:
- Infrared thermometer for non-contact measurement of surface temperatures
- Accurate results thanks to its 30:1 optics and high resolution processor
- One-handed operation is easy thanks to the gun-style design
- Hands-Free Carry Two durable hoist points make transporting the recovery machine easier. Includes the hilmor HVAC/R Carrying Strap.
Specs
Storage temperature | -40 to +158 F |
---|---|
Operating temperature | -4 to +122 F |
Battery type | 9 volt battery |
Battery life | 15 hr |
Weight | 7 oz |
Dimensions | 7.48 x 2.95 x 1.5 in |
Probe type Type K | |
---|---|
Meas. Range | -58 to +932 F |
Probe type Infrared | |
Meas. Range | -22 to +752 F |
Accuracy | 2.7 F or 1.5% of rdg. (+32.1 to +752 F) 3.6 F or 2% of rdg. (-22 to +32 F) |
Includes
Videos
Resources
Software / App