null

UEi DL379B Digital Clamp Meter, Non-True-RMS

SKU:
DL379B
MPN:
DL379B
Minimum Purchase:
1 unit
Product Discontinued

Description

UEi DL379B Digital Clamp Meter

Newly upgraded with dual level NCV and CAT IV 300V rating

The DL379B is fully featured HVAC/R meter with temperature, detachable head, worklight, safety lock for the input jacks, and a new EasyView Display making readings clear in bright sunlight as well as dark work environments.

Features

  • Dual Display
  • Input Jack Lock
  • Worklight
  • User temperature calibration
  • Dual range NCV
  • Low Battery Display Lock
  • EasyView High Contrast Backlight Display
  • Magnetic Mount
  • User Temperature Calibration
  • Detachable Head
  • Test lead storage with holder on clamp head
  • Auto Off
  • 3 Year warranty

Functions

  • 750V AC/1000V DC
  • AC current: 2000µA
  • AC current (Clamp): 400A
  • Temperature range (K-Type): -22° to 752°F (-30° to 400°C)
  • Capacitance: 2000µF
  • Frequency/ Duty cycle
  • Resistance: 40MO
  • Frequency 199.9KHz
  • Duty cycle: 99%
  • Resistance: 40MO
  • Non-contact voltage detection: 24V to 600V AC
  • Diode Test
  • Continuity

Specs

DC Volts
Range Resolution Accuracy Overload Protection
400mV 0.1mV ±(0.5% + 4 dgts) 1000V RMS
4V 1mV
40V 10mV
400V 100mV
1000V 1V ±0.8% + 10
AC Volts (45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
400mV 0.1mV ±(2.0% +5 dgts) 750V RMS
4V 1mV
40V 10mV
400V 100mV
750V 1V
AC Amps Measurement - Jaw Input (45~400Hz)
Range Resolution Accuracy Overload Protection
40A 0.01A ±(2.9% + 15 dgts) 400A
400A 0.1A ±(1.9% + 8 dgts)
DC Low Amps Measurement (Test Lead Input)
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±(1.2% + 3 dgts) 2000µA/600V RMS
2000µA 0.1µA
AC Low Amps Measurement (Test Lead Input 45Hz to 400Hz)
Range Resolution Accuracy Overload Protection
400µA 0.01µA ±(2.0% + 5 dgts) 2000µA/600V RMS
2000µA 0.1µA ±(1.5% + 5 dgts)
Resistance
Range Resolution Accuracy Overload Protection
400Ω 100mΩ ±(1.0% + 4 dgts) 600V RMS
4kΩ
40kΩ 10Ω
400kΩ 100Ω
4MΩ 1kΩ
40MΩ 10kΩ ±(2.0% + 4 dgts)
Capacitance
Range Resolution Accuracy Overload Protection
40nF 0.01nF ±(3.5% + 6 dgts) 600V RMS
400nF 0.1nF
4µF 0.001µF
40µF 0.01µF
400µF 0.1µF
2000µF 1µF
Duty Cycle
Range Accuracy Overload Protection
01. to 99.9% ±(0.2% per kHz +0.1%) + 5 counts 600V RMS
Diode Test
Range Open Circuit V Test Current Overload Protection
2.0V <1.6V DC 0.25mA 600V RMS
Frequency
Range Resolution Accuracy Overload Protection
9.999Hz 0.001Hz ±(0.1% + 4 dgts) 600V RMS
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
99.99kHz 10Hz
199.9kHz 100Hz
Continuity
Open Circuit Voltage <0.44V Overload Protection
Threshold Approximately <50Ω 600V RMS
Temperature
Range Resolution Accuracy Overload Protection
-22° ~ 14°F 0.1°F ±(1.0% +5.4°F) 30V RMS
15° ~ 752°F ±(1.0% + 3.6°F)
(-30° ~ -10°C) (0.1°C) (1.0% +3.0°C)
(-9° ~ 400°C) (±1.0% + 2.0°C)

Includes

  • (1) UEi DL379B Digital Clamp Meter
  • (1) Test Leads
  • (2) AAA Batteries
  • (1) Pouch
  • (1) Manual

Videos

Resources

View AllClose