USED TEC Minneapolis Blower Door System with DG-700

DG-700 Gauge needs to be calibrated

The Minneapolis Blower Door has long been recognized as one of the best designed and supported building air tightness testing systems in the world. Combined with specialized accessories and testing procedures developed by The Energy Conservatory, the Minneapolis Blower Door is widely used by utility DSM programs, energy raters, HVAC contractors and weatherization professionals.

Features:

  • Lightweight, rugged, injection molded fan housing
  • Precise, stable flow measurements without the need for gauge dampening
  • The Model 3 Fan provides quick and accurate flow measurements from 300 to 6,100 CFM (includes Flow Rings A and B)
  • Optional Flow Rings C, D and E will measure down to 11 CFM
  • Variable fan speed control (solid state - cruise control compatible)
  • Operates on110V/60 Hz
The Energy Conservatory's Blower Door can be configured with 2 or 3 fans in a single door frame for testing larger buildings or dwellings (see related products below for more information on these multi-fan systems).
TECTITEâ„¢ Building Airtightness Testing Software (Windows Based)
• Calculates building airtightness test results including leakage areas, ACH50, CFM50, building leakage curve, estimated natural and design infiltration rates and the estimated savings of air-sealing.
• Compatible with both manual blower door tests and automated tests using a DG-700 or APT System.
• Calculation procedures and reports are done in accordance with CGSB-149.10-M86. Mechanical ventilation requirements calculated in accordance with ASHRAE 62.2.
• Easy to use data entry screens, file storage and file retrieval features.
• RESNET testing options

Specs

Type Model 3 Blower Door Fan
Maximum Flow 6,100 CFM (free air), 5,250 CFM (at 50 Pa), 4900 CFM (at 75 Pa).
Minimum Flow 20" inlet diameter, 10.25" length
Weight 33 lbs. with FlowRings A&B
Flow Accuracy +/- 3% (using DG-700 or APT system). Rings D and E +/- 4% or 1 CFM, whichever is greater
Calibration Meets ASTM Standard E779-10, E1554-07, CGSB-149.10-M86, RESNET 2012, EN 13829 and ATTMA TS1 and NFPA 2001.
Power 110V
Adjustable Frame Material Extruded Aluminum
Width 28" - 40" adjustable
Height 52" - 96" adjustable
Seal EPDM flexible gasket
Panel Material Nylon w/ built-in vinyl window
DG-700, APT System See Specifications on Digital Pressure Gauges and Automated Performance Testing System pages

Includes

Includes:

  • Fan with variable speed controller and control cable
  • Two flow rings (A and B) and No-flow plate
  • DG-700 Pressure and Flow Gauge (only (1) gauge needed for each fan)
  • TECTITEâ„¢ Building Airtightness Testing Software
  • 16-foot (5 meter) USB cable
  • Fabric door panel with viewing window
  • Five piece adjustable aluminum door frame and frame case
  • Padded attaché case for gauge, manuals, tubing, speed controller and fabric panel, with room for a laptop computer and other documents