MSRP: $334.99
Price: $319.99
— You save $15.00

Description

Fluke 417D Laser Distance Meter and 62 MAX+ IR Thermometer Kit

The HVAC Troubleshooting Kit

The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy-to-use 417D Laser Distance Meter has everything you need to configure HVAC layouts and troubleshoot electrical problems. For electrical devices use the IR thermometer to test overheating issues and for HVAC layout, use the 417D to configure layout distance or area and use continuous measurement for marking references.

Fluke 417D Laser Distance Meter Key Features & Benefits

  • Continuous measurement capable: adjusting as you move closer and farther from your target
  • Quickly calculate area (sq. feet/meters)
  • 1-meter drop tested and IP54 rated: built to withstand rainy or dusty conditions
  • Great for interior and exterior applications

Fluke 417D Laser Distance Meter Key Features & Benefits

  • Dust and water-resistant: IP54 rated
  • Rugged: 3-meter (9.8-foot) drop tested
  • Ergonomically designed: Completely redesigned for a more natural hand fit
  • Large, backlit display: Makes data easier to read, even in dark areas

Specs

Fluke 417D
Typical range [1] 0.2-40 m / 0.6-131 ft
Typical measuring tolerance* [1] 2.0 mm ± 1.5 mm / ± 0.06 in ***
Maximum measuring tolerance [2] ± 3.0 mm / 0.12 in ***
Accuracy up to 10m (+/-) ± 2 mm
Display 2 line / 1 mm / 1/32 in
Display illumination Yes
Laser point at distance 6/30/60 mm (10/40/100 m)
Area Yes
Units setting (smallest units displayed) 0.000m, 0' 00'' 1/32, 0 in 1/32
Auto laser switch off 90 sec
Auto power switch off 180 sec
Laser class II
Laser type 635 nm, <1 mW
Protection class IP54
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements
Size (Hx W x D) 11.9 x 3.8 x 2.6 cm
Drop test 1 meter
Weight (with batteries) 95g (3.35 oz)
Temperature range: Storage -25 °C to 70 °C (-13 °F to 158 °F)
Temperature range: Operation -10 °C to 50 °C (14 °F to 122 °F)
Calibration cycle Not applicable
Maximum relative humidity 85 % @ 20°F to 120 °F (-7 °C to 50 °C)
Safety CAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)
EMC 61326-1:2006
  • [1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C (13 °F).
  • [2] Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to +50 °C (14 °F to +122 °F).
  • [3] Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft) and to 0.15 mm/m (0.005 in/ft) for distances above 30 m (98.4 ft).
  • [4] Applies for 100 % target reflectivity, background illumination between 10,000 lux and 30,000 lux.
  • [5] After user calibration. Additional angle related deviation of ± 0.01° per degree up to ± 45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ± 0.1°.
Fluke 62 Max+
Temperature range -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy (Calibration geometry with ambient temperature 23 °C +/- 2 °C) ± 1.0 °C or ± 1.0 % of reading, whichever is greater
± 2.0 °C at -10 °C to 0 °C
± 3.0 °C at -30 °C to -10 °C
Optical resolution 12:1 (calculated at 90 % energy)
Response time (95 %) < 300 ms (95 % of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Display resolution 0.1 °C (0.2 °F)
Repeatability (% of reading) ± 0.5 % of reading or ± 0.5 °C (whichever is greater)
Power 1 AA alkaline battery
Battery life 8 hours with laser and backlight on
Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm
(6.88 x 3.34 x 2.95) inches
Operating temperature 0 °C to 50 °C (32 °F to 122°F)
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F) (without battery)
Operating humidity Non-condensing @ ≤ 10 °C (50 °F)
≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F)
≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F)
≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F)
Operating altitude 2000 meters above mean sea level
Storage altitude 12,000 meters above mean sea level
Drop test 3 meters
Implement standard Q/ASF01
Standards and agency approval Compliance: IEC 61010-1: Pollution Degree 2
Laser safety: IEC 60825-1 Class 2, 650 nm, < 1 mW
Ingress protection rating: IP 54 per IEC 60529
Warranty 3 years

Includes

  • (1) Fluke 417D Laser Distance Meter
  • (1) Fluke 62 MAX+ IR Thermometer
View AllClose