null

TSI 9545-A VelociCalc Air Velocity Meter for Humidity, Temperature, and Velocity with Calculation and Data Logging, Articulating Telescopic Probe

SKU:
9545-A
MPN:
9545-A
Minimum Purchase:
1 unit
MSRP: $1,870.00
Price: $1,683.00
— You save $187.00

Description

TSI 9545-A VelociCalc Air Velocity Meter for Humidity, Temperature, and Velocity with Calculation and Data Logging, Articulating Telescopic Probe

Measures humidity/velocity/temp, calculates flow/wet bulb/dew point, data logging

The VelociCalc 9545 meter simultaneously measures and data logs several ventilation parameters using a single probe with multiple sensors. Ideal for optimizing HVAC system performance, commissioning, plant maintenance, critical environment certification and duct traverses. Includes the articulated probe.

Key Features & Benefits

  • Simple to operate
  • Accurate air velocity measurement
  • 0 to 6,000 ft/min (0 to 30 m/s) range
  • Displays humidity as % relative humidity, wet bulb or dew point temperature
  • Calculates volumetric flow and actual/standard velocity
  • Displays up to three measurements simultaneously
  • Data log 12,700+ samples and 100 test IDs
  • Articulated probe

Applications

  • HVAC system performance
  • Commissioning
  • Plant maintenance
  • Critical environment certification
  • Duct traverses

Specs

Velocity Measurement
Range 0 to 6000 ft/min (0 to 30 m/s)
Accuracy ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater
Resolution 1 ft/min (0.01 m/s)
Duct Size
Range 1 to 250 in. in 0.1 in. increments (1 to 635 cm in 0.1 cm increments)
Volumetric Flowrate
Range Function of actual velocity and duct size
Temperature Measurement
Range 0 to 200°F (-18 to 93°C)
Accuracy ±0.5°F (±0.3°C)
Resolution 0.1°F (0.1°C)
Humidity Measurement
Range 5 to 95% RH
Accuracy ±3% RH
Resolution 0.1% RH
Wet Bulb Temperature
Range 40 to 140°F (5 to 60°C)
Resolution 0.1°F (0.1°C)
Data Logging
Capacity 12,700+ samples and 100 test IDs (1 sample = up to 14 measurement types)
Response Time
Velocity 200 msec
Temperature 2 minutes (to 66% of final value)
Humidity <1 minute (to 66% of final value)
General Specs
Operating Temp (Electronics) 40 to 113°F (5 to 45°C)
Operating Temp (Probe) 0 to 200°F (-18 to 93°C)
Storage Temperature -4 to 140°F (-20 to 60°C)
Instrument Dimensions 3.3 in. x 7.0 in. x 1.8 in. (8.4 cm x 17.8 cm x 4.4 cm)
Articulating Probe 6.0 in. length, 0.38 in. knuckle diameter
Weight 0.6 lbs (0.27 kg) with batteries
Power Requirements Four AA batteries (included) or 9 VDC, 300 mA minimum AC adapter

Includes

  • (1) TSI 9545 VelociCalc Air Velocity Meter with Articulating Probe
  • (4) AA Batteries
  • (1) USB cable
  • (1) Hard carrying case
  • (1) Certificate and Manual