Description
UEi 511KIT Heat Pump Install Kit with Clamp Meter, Leak Detector, Manometer, and Smart Probes
Featuring the DL579, RLD15B, HUB8, and EM201B.
This Kit provides the recommended test instruments required by heat pump start up manuals for proper installation and maintenance. Most equipment warranties require initial install readings to be documented upon installation. The 511KIT is packed in a UEi Tool Backpack. Built rugged, waterproof base, two compartments with inner pocket options and includes D-clip.
This Kits helps confirm:
- Manufacturer requirements to maintain warranty
- CFM via external static pressure test
- System is free from refrigerant leaks
- Proper high voltage to power supply and ground
- Low voltage meets wiring diagram requirements
- Evacuation Suction & Liquid valves
- Temperatures of Suction & Liquid lines
- Superheat and Subcool values for adjustments
UEi DL579 True RMS Clamp Meter with Temperature and Capacitance
True-RMS Dual Display 600A HVAC/R Clamp Meter w/ Temperature & Capacitance
Application
Measure capacitance, voltage, circuit continuity, resistance, temperature via K-Type thermocouples and diode malfunctions. Check system boards and live wires.
Functions: | |
---|---|
TRMS: | Yes |
AC Volts: | 750VAC |
DC Volts: | 1000VDC |
AC current (amps): | 600A AC |
AC micro current (amps): | 2000µA |
DC micro current (amps) | 2000µA |
DC micro volts: | 600mV |
AC micro volts: | 600mV |
Resistance (Ohms): | 60MΩ |
Capacitance (Farads): | 6000µF |
Frequency (Hertz): | 99.99kHz |
Duty cycle: | 1.0 to 99.0% |
Temperature: | -328° to 2462°F |
Continuity: | Yes |
Diode: | Yes |
NCV Detection: | Yes |
LRA Inrush: | Yes |
Low Z: | Yes | Features: |
Hold: | Yes |
Min/Max: | Yes |
Ranging: | Auto/Manual |
Auto power off: | Yes |
Display count: | 6000 |
Low battery warning: | Yes |
Backlight: | Yes |
Dual display: | Yes |
Temperature Inputs: | K-Type |
Protective boot or overmolding: | Yes |
Magnetic mount: | Optional |
Warranty: | 1 Year limited |
Audible and visual alerts: | Yes |
K-type input: | Yes |
Digital: | Yes |
UEi HUB8 Smart Refrigeration Probes Deluxe Kit with Vacuum Gauge
View All Indoor and Outdoor AC/R System Parameters from One Location
The HUB8 Smart Refrigeration Probes Deluxe Kit is the most complete and convenient wireless refrigeration probe kit available today. The HUB8 makes it easier for you to service and charge air-conditioning and refrigeration systems. The addition of the wireless Vacuum Gauge and Outdoor Thermometer probe integrates real-time Target Superheat, Evacuation and Rise Test calculations into the App. This provides a more accurate, efficiency and cost-effective charge on the system allowing all your vacuum, refrigeration and air parameters to be viewed from one location.
Features:
- Wireless vacuum gauge probe
- Real time target superheat calculation
- Pressure probes w/ 180° articulation
- Refrigerant pass through port
- Wireless pipe clamps
- Dual mode vacuum screen for evacuation & rise tests
- Temperature split and psychrometric calculations
- Easy drag-and-drop probe connections
- Wireless distance of 350ft pending environment
- Wireless Vacuum Gauge Probe
- Range 0-20,000 Microns
- 1-micron Resolution, ±5% reading ±5 microns accuracy
- Oil contamination and sensor failure detection
- Instant warm-up and response time
- 1/4" Nickel-plated flare fitting
- 45° coupler included
- Wireless Pressure Probes
- Pass through refrigerant port for easily adding or recovering refrigerant from the system without disconnecting probes
- 180° rotation for easy use in cramped spaces
- Range 0 to 725 psig, resolution 0.1 psi.
- Accuracy 0.5%FS (@25±3°C), total 1%FS
- Wireless Pipe Clamps
- Sensor is thermally isolated from ambient temperatures
- High accuracy thermistor provides better results than thermocouples and doesn't require field calibration
- Slim design fits into tight spaces
- Range 32° to 176°F (0° to 80°C), resolution 0.1°F.
- Response time < 30 sec. Accuracy ±0.6°F (±0.3°C).
- Wireless Hygrometer Probes
- Slimmest 1/4" hygrometer probe means smaller drill holes
- Magnetic mount and locking probe holds WHP1 to plenum for hands-free operation
- Temp range: 32° to 140°F (0° to 60°C), Accuracy: ±0.5°F (±0.3°C)
- Relative Humidity: 0 to 100% (0.1% resolution, ±3% accuracy from 20 to 80% ±5% otherwise)
- Wireless Outdoor Temperature Probe
- Temperature range 32° - 180°F (0° - 82°C)
- Magnetic hanger allows for temperature measurement in direct air stream
- Compact lightweight design
UEi EM201B Dual Input Differential Manometer
A Digital, Time Saving Alternative to U-Tube Pressure Measurement.
- EM201B (Dual input) Measures ±60 inches water column .001 wg resolution below 9.999”
- Ruggedized with sturdy metal fittings
- Rubber-boot with built-in magnet
- Measures in inches water column, mBar, PSI, and Pa (auto range to hPa)
- Dynamic Min/Max value capture
- Data hold
- Auto power off
- Back-lit display
- Three year limited warranty
UEI RLD15B Refrigerant Leak Detector
Detects industry standard refrigerants including, but not limited to: HFC, HCFC, CFC (R-134A, R-410A sensitivity = 0.05 oz/yr)
Specs
AC Amps Measurement - Jaw input | |||
---|---|---|---|
Range | Resolution | Accuracy | Overload Protection |
60.00A | 0.01A | ±2.0% +8dgts | 600V RMS |
600.0A | 0.1A | ||
Minimum Current for Clamp Measurement: 0.3A | |||
DC Microamps Measurement - Test lead input | |||
Range | Resolution | Accuracy | Overload Protection |
600.00µA | 0.1µA | ±1.2% +3dgts | 600V RMS |
2000µA | 1µA | ||
AC Microamps Measurement -Test lead input | |||
Range | Resolution | Accuracy | Overload Protection |
600.0µA | 0.1µA | ±2.0% +5dgts | 600V RMS |
2000µA | 1µA | ||
45Hz to 400Hz True RMS | |||
DC Volts Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
600.0mV | 0.1mV | ±0.5% +4dgts | 1000V RMS |
6.000V | 0.001V | ||
60.00V | 0.01V | ||
600.0V | 0.1V | ||
1000V | 1V | ±0.8% +10dgts | |
AC Volts Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
600.0mV | 0.1mV | ±2.0% +5dgts | 750V RMS |
6.000V | 0.001V | ||
60.00V | 0.01V | ||
600.0V | 0.1V | ||
750V | 1V | ||
45Hz to 400Hz True RMS | |||
Ohms Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
600.0Ω | 0.1Ω | ±1.0% +4dgts | 600V RMS |
6.000kΩ | 0.001kΩ | ||
60.00kΩ | 0.01kΩ | ||
600.0kΩ | 0.1kΩ | ||
6.000MΩ | 0.001MΩ | ||
60.00MΩ | 0.01MΩ | ±2.0% +4dgts | |
Diode Test | |||
Range | Open Circuit Voltage | Test Current (Typical) | Overload Protection |
6.0V | < 3.0V DC | 0.25mA | 600V RMS |
Capacitance Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
60.00nF | 0.01nF | 3.5% +6dgts | 600V RMS |
600.0nF | 0.1nF | ||
6.000µF | 0.001µF | ||
60.00µF | 0.01µF | ||
600.0µF | 0.1µF | ||
6000µF | 1µF | ||
Temperature Measurement | |||
Range | Resolution | Accuracy | Overload Protection |
-328° to 999°F | 0.1°F | ±(1.0% +3.6°F) | 30V RMS |
-200° to 999°C | 0.1°C | ±(1.0% +2.0°C) | |
1000° to 2462°F | 1°F | ±(1.0% +3°F) | |
1000° to 1350°C | 1°C | ±(1.0% +2°C) | |
Frequency Measurement - Test lead input | |||
Range | Resolution | Accuracy | Overload Protection |
99.99Hz | 0.01Hz | 0.1% +4dgts | 1000V RMS |
999.9Hz | 0.1Hz | ||
9.999kHz | 0.001kHz | ||
99.99kHz | 0.01kHz | ||
Minimum Frequency: 0.5Hz, Sensitivity: > 10% of each AC volt range except 4V (>20%) range only | |||
Duty Cycle | |||
Range | Accuracy | Overload Protection | |
1.0 to 99.0% | ±(0.2% per kHz +0.1% +5 dgts) | 1000V RMS | |
Audible Continuity Measurement | |||
Open Circuit Voltage < 0.64V | Overload Protection | ||
Threshold Approx : < 40Ω | 600V RMS |
Measurement Range | -40" to +40" WG -100 to +100 mBar |
Accuracy | ±0.02"WG < 2"WG ±1%RDG > 2"WG |
Resolution | 0.001" -9.999" to +9.999" WG 0.01" for < -10" or > +10" WG |
Operating Range | 32° -104°F (0° - 40°C) 10 - 90% RH non condensing |
Battery Life | 40 hours min with alkaline battery |
Includes
- (1) UEi DL579 Clamp Meter 400Amps
- (1) Test Leads (ATL55)
- (2) Temp Probe (ATT29)
- (1) Alligator Clips (AAC3)
- (2) Batteries (AAA)
- (1) Zippered Pouch
- (1) Manual
- (1) RLD15B Refrigerant Leak Detector
- (1) Sensors filters 5
- (1) Leak test vial
- (4) Batteries
- (1) Hard carrying case
- (1) Wireless Vacuum Gauge Probe
- (2) Wireless Hygrometer Probes
- (2) Wireless Pressure Probes
- (2) Wireless Pipe Clamps
- (1) Wireless Outdoor Temperature Probe
- (2) AAA Batteries
- (7) AA Batteries
- (1) Carrying Case
- (1) 45° coupler
- (1) Color-coded Indication stickers pack
- (1) Dual Input Electronic Manometer (EM201E)
- (2) Magnetic static pressure tips (ASP1)
- (2) Brass valve fitting connector (BF100)
- (1) Soft carrying case (AC319)
- (1) Pressure tubing
- (1) 9V Battery
Videos
Resources
Software / App
Download the UEi Hub App for your Android or iOS device
Free Intuitive App Features Vacuum, Refrigeration & Air Calculations
- Liquid and Suction line pressures, temperatures, saturations and outdoor dry bulb
- Superheat, subcooling and target superheat
- Delta and target delta temperatures
- Air Return and supply relative humidity, dry bulb, wet bulb, dew point and enthalpy
- Vacuum & deepest vacuum
- Evacuation and rise limit target, timer
- H2O saturation point indication
- Selectable units of measure
- High altitude compensation
- 57 refrigerants list and favorites refrigerant menu