UEi 511KIT Heat Pump Install Kit with Clamp Meter, Leak Detector, Manometer, and Smart Probes

Featuring the DL579, RLD15B, HUB8, and EM201B.

This Kit provides the recommended test instruments required by heat pump start up manuals for proper installation and maintenance. Most equipment warranties require initial install readings to be documented upon installation. The 511KIT is packed in a UEi Tool Backpack. Built rugged, waterproof base, two compartments with inner pocket options and includes D-clip.

This Kits helps confirm:

  • Manufacturer requirements to maintain warranty
  • CFM via external static pressure test
  • System is free from refrigerant leaks
  • Proper high voltage to power supply and ground
  • Low voltage meets wiring diagram requirements
  • Evacuation Suction & Liquid valves
  • Temperatures of Suction & Liquid lines
  • Superheat and Subcool values for adjustments

UEi DL579 True RMS Clamp Meter with Temperature and Capacitance

True-RMS Dual Display 600A HVAC/R Clamp Meter w/ Temperature & Capacitance


Application
Measure capacitance, voltage, circuit continuity, resistance, temperature via K-Type thermocouples and diode malfunctions. Check system boards and live wires.

Functions:
TRMS: Yes
AC Volts: 750VAC
DC Volts: 1000VDC
AC current (amps): 600A AC
AC micro current (amps): 2000µA
DC micro current (amps) 2000µA
DC micro volts: 600mV
AC micro volts: 600mV
Resistance (Ohms): 60MΩ
Capacitance (Farads): 6000µF
Frequency (Hertz): 99.99kHz
Duty cycle: 1.0 to 99.0%
Temperature: -328° to 2462°F
Continuity: Yes
Diode: Yes
NCV Detection: Yes
LRA Inrush: Yes
Low Z: Yes
Features:
Hold: Yes
Min/Max: Yes
Ranging: Auto/Manual
Auto power off: Yes
Display count: 6000
Low battery warning: Yes
Backlight: Yes
Dual display: Yes
Temperature Inputs: K-Type
Protective boot or overmolding: Yes
Magnetic mount: Optional
Warranty: 1 Year limited
Audible and visual alerts: Yes
K-type input: Yes
Digital: Yes

UEi HUB8 Smart Refrigeration Probes Deluxe Kit with Vacuum Gauge

View All Indoor and Outdoor AC/R System Parameters from One Location

The HUB8 Smart Refrigeration Probes Deluxe Kit is the most complete and convenient wireless refrigeration probe kit available today. The HUB8 makes it easier for you to service and charge air-conditioning and refrigeration systems. The addition of the wireless Vacuum Gauge and Outdoor Thermometer probe integrates real-time Target Superheat, Evacuation and Rise Test calculations into the App. This provides a more accurate, efficiency and cost-effective charge on the system allowing all your vacuum, refrigeration and air parameters to be viewed from one location.

Features:

  • Wireless vacuum gauge probe
  • Real time target superheat calculation
  • Pressure probes w/ 180° articulation
  • Refrigerant pass through port
  • Wireless pipe clamps
  • Dual mode vacuum screen for evacuation & rise tests
  • Temperature split and psychrometric calculations
  • Easy drag-and-drop probe connections
  • Wireless distance of 350ft pending environment
  • Wireless Vacuum Gauge Probe
    • Range 0-20,000 Microns
    • 1-micron Resolution, ±5% reading ±5 microns accuracy
    • Oil contamination and sensor failure detection
    • Instant warm-up and response time
    • 1/4" Nickel-plated flare fitting
    • 45° coupler included
  • Wireless Pressure Probes
    • Pass through refrigerant port for easily adding or recovering refrigerant from the system without disconnecting probes
    • 180° rotation for easy use in cramped spaces
    • Range 0 to 725 psig, resolution 0.1 psi.
    • Accuracy 0.5%FS (@25±3°C), total 1%FS
  • Wireless Pipe Clamps
    • Sensor is thermally isolated from ambient temperatures
    • High accuracy thermistor provides better results than thermocouples and doesn't require field calibration
    • Slim design fits into tight spaces
    • Range 32° to 176°F (0° to 80°C), resolution 0.1°F.
    • Response time < 30 sec. Accuracy ±0.6°F (±0.3°C).
  • Wireless Hygrometer Probes
    • Slimmest 1/4" hygrometer probe means smaller drill holes
    • Magnetic mount and locking probe holds WHP1 to plenum for hands-free operation
    • Temp range: 32° to 140°F (0° to 60°C), Accuracy: ±0.5°F (±0.3°C)
    • Relative Humidity: 0 to 100% (0.1% resolution, ±3% accuracy from 20 to 80% ±5% otherwise)
  • Wireless Outdoor Temperature Probe
    • Temperature range 32° - 180°F (0° - 82°C)
    • Magnetic hanger allows for temperature measurement in direct air stream
    • Compact lightweight design

UEi EM201B Dual Input Differential Manometer

A Digital, Time Saving Alternative to U-Tube Pressure Measurement.

  • EM201B (Dual input) Measures ±60 inches water column .001 wg resolution below 9.999”
  • Ruggedized with sturdy metal fittings
  • Rubber-boot with built-in magnet
  • Measures in inches water column, mBar, PSI, and Pa (auto range to hPa)
  • Dynamic Min/Max value capture
  • Data hold
  • Auto power off
  • Back-lit display
  • Three year limited warranty

UEI RLD15B Refrigerant Leak Detector

Detects industry standard refrigerants including, but not limited to: HFC, HCFC, CFC (R-134A, R-410A sensitivity = 0.05 oz/yr)

Specs

DL579 Specs

AC Amps Measurement - Jaw input
Range Resolution Accuracy Overload Protection
60.00A 0.01A ±2.0% +8dgts 600V RMS
600.0A 0.1A
Minimum Current for Clamp Measurement: 0.3A
DC Microamps Measurement - Test lead input
Range Resolution Accuracy Overload Protection
600.00µA 0.1µA ±1.2% +3dgts 600V RMS
2000µA 1µA
AC Microamps Measurement -Test lead input
Range Resolution Accuracy Overload Protection
600.0µA 0.1µA ±2.0% +5dgts 600V RMS
2000µA 1µA
45Hz to 400Hz True RMS
DC Volts Measurement
Range Resolution Accuracy Overload Protection
600.0mV 0.1mV ±0.5% +4dgts 1000V RMS
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
1000V 1V ±0.8% +10dgts
AC Volts Measurement
Range Resolution Accuracy Overload Protection
600.0mV 0.1mV ±2.0% +5dgts 750V RMS
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
750V 1V
45Hz to 400Hz True RMS
Ohms Measurement
Range Resolution Accuracy Overload Protection
600.0Ω 0.1Ω ±1.0% +4dgts 600V RMS
6.000kΩ 0.001kΩ
60.00kΩ 0.01kΩ
600.0kΩ 0.1kΩ
6.000MΩ 0.001MΩ
60.00MΩ 0.01MΩ ±2.0% +4dgts
Diode Test
Range Open Circuit Voltage Test Current (Typical) Overload Protection
6.0V < 3.0V DC 0.25mA 600V RMS
Capacitance Measurement
Range Resolution Accuracy Overload Protection
60.00nF 0.01nF 3.5% +6dgts 600V RMS
600.0nF 0.1nF
6.000µF 0.001µF
60.00µF 0.01µF
600.0µF 0.1µF
6000µF 1µF
Temperature Measurement
Range Resolution Accuracy Overload Protection
-328° to 999°F 0.1°F ±(1.0% +3.6°F) 30V RMS
-200° to 999°C 0.1°C ±(1.0% +2.0°C)
1000° to 2462°F 1°F ±(1.0% +3°F)
1000° to 1350°C 1°C ±(1.0% +2°C)
Frequency Measurement - Test lead input
Range Resolution Accuracy Overload Protection
99.99Hz 0.01Hz 0.1% +4dgts 1000V RMS
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99kHz 0.01kHz
Minimum Frequency: 0.5Hz, Sensitivity: > 10% of each AC volt range except 4V (>20%) range only
Duty Cycle
Range Accuracy Overload Protection
1.0 to 99.0% ±(0.2% per kHz +0.1% +5 dgts) 1000V RMS
Audible Continuity Measurement
Open Circuit Voltage < 0.64V Overload Protection
Threshold Approx : < 40Ω 600V RMS

EM201B Specs

Measurement Range -40" to +40" WG
-100 to +100 mBar
Accuracy ±0.02"WG < 2"WG
±1%RDG > 2"WG
Resolution 0.001" -9.999" to +9.999" WG
0.01" for < -10" or > +10" WG
Operating Range 32° -104°F (0° - 40°C)
10 - 90% RH non condensing
Battery Life 40 hours min with alkaline battery

Includes

  • (1) UEi DL579 Clamp Meter 400Amps
  • (1) Test Leads (ATL55)
  • (2) Temp Probe (ATT29)
  • (1) Alligator Clips (AAC3)
  • (2) Batteries (AAA)
  • (1) Zippered Pouch
  • (1) Manual
  • (1) RLD15B Refrigerant Leak Detector
  • (1) Sensors filters 5
  • (1) Leak test vial
  • (4) Batteries
  • (1) Hard carrying case
  • (1) Wireless Vacuum Gauge Probe
  • (2) Wireless Hygrometer Probes
  • (2) Wireless Pressure Probes
  • (2) Wireless Pipe Clamps
  • (1) Wireless Outdoor Temperature Probe
  • (2) AAA Batteries
  • (7) AA Batteries
  • (1) Carrying Case
  • (1) 45° coupler
  • (1) Color-coded Indication stickers pack
  • (1) Dual Input Electronic Manometer (EM201E)
  • (2) Magnetic static pressure tips (ASP1)
  • (2) Brass valve fitting connector (BF100)
  • (1) Soft carrying case (AC319)
  • (1) Pressure tubing
  • (1) 9V Battery

Videos

Software / App

Download the UEi Hub App for your Android or iOS device
Free Intuitive App Features Vacuum, Refrigeration & Air Calculations

  • Liquid and Suction line pressures, temperatures, saturations and outdoor dry bulb
  • Superheat, subcooling and target superheat
  • Delta and target delta temperatures
  • Air Return and supply relative humidity, dry bulb, wet bulb, dew point and enthalpy
  • Vacuum & deepest vacuum
  • Evacuation and rise limit target, timer
  • H2O saturation point indication
  • Selectable units of measure
  • High altitude compensation
  • 57 refrigerants list and favorites refrigerant menu

Google Play Store Apple App Store