UEi DL579 True RMS Clamp Meter with Temperature and Capacitance

True-RMS Dual Display 600A HVAC/R Clamp Meter w/ Temperature & Capacitance


Application
Measure capacitance, voltage, circuit continuity, resistance, temperature via K-Type thermocouples and diode malfunctions. Check system boards and live wires.

Functions:
TRMS: Yes
AC Volts: 750VAC
DC Volts: 1000VDC
AC current (amps): 600A AC
AC micro current (amps): 2000µA
DC micro current (amps) 2000µA
DC micro volts: 600mV
AC micro volts: 600mV
Resistance (Ohms): 60MΩ
Capacitance (Farads): 6000µF
Frequency (Hertz): 99.99kHz
Duty cycle: 1.0 to 99.0%
Temperature: -328° to 2462°F
Continuity: Yes
Diode: Yes
NCV Detection: Yes
LRA Inrush: Yes
Low Z: Yes
Features:
Hold: Yes
Min/Max: Yes
Ranging: Auto/Manual
Auto power off: Yes
Display count: 6000
Low battery warning: Yes
Backlight: Yes
Dual display: Yes
Temperature Inputs: K-Type
Protective boot or overmolding: Yes
Magnetic mount: Optional
Warranty: 1 Year limited
Audible and visual alerts: Yes
K-type input: Yes
Digital: Yes
Standards
UL Listed: UL 61010-1: 2012
ETL Listed: cETLus
CAT Rating: CATIII 600V
Includes
Manual (Eng): Yes
Test Leads: ATL55
Alligator clips: AAC3
Batteries: 2 (AAA)
Pouch/Cases: Zippered Pouch
Temp Probe: 2 (ATT29)

Specs

AC Amps Measurement - Jaw input
Range Resolution Accuracy Overload Protection
60.00A 0.01A ±2.0% +8dgts 600V RMS
600.0A 0.1A
Minimum Current for Clamp Measurement: 0.3A
DC Microamps Measurement - Test lead input
Range Resolution Accuracy Overload Protection
600.00µA 0.1µA ±1.2% +3dgts 600V RMS
2000µA 1µA
AC Microamps Measurement -Test lead input
Range Resolution Accuracy Overload Protection
600.0µA 0.1µA ±2.0% +5dgts 600V RMS
2000µA 1µA
45Hz to 400Hz True RMS
DC Volts Measurement
Range Resolution Accuracy Overload Protection
600.0mV 0.1mV ±0.5% +4dgts 1000V RMS
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
1000V 1V ±0.8% +10dgts
AC Volts Measurement
Range Resolution Accuracy Overload Protection
600.0mV 0.1mV ±2.0% +5dgts 750V RMS
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
750V 1V
45Hz to 400Hz True RMS
Ohms Measurement
Range Resolution Accuracy Overload Protection
600.0Ω 0.1Ω ±1.0% +4dgts 600V RMS
6.000kΩ 0.001kΩ
60.00kΩ 0.01kΩ
600.0kΩ 0.1kΩ
6.000MΩ 0.001MΩ
60.00MΩ 0.01MΩ ±2.0% +4dgts
Diode Test
Range Open Circuit Voltage Test Current (Typical) Overload Protection
6.0V < 3.0V DC 0.25mA 600V RMS
Capacitance Measurement
Range Resolution Accuracy Overload Protection
60.00nF 0.01nF 3.5% +6dgts 600V RMS
600.0nF 0.1nF
6.000µF 0.001µF
60.00µF 0.01µF
600.0µF 0.1µF
6000µF 1µF
Temperature Measurement
Range Resolution Accuracy Overload Protection
-328° to 999°F 0.1°F ±(1.0% +3.6°F) 30V RMS
-200° to 999°C 0.1°C ±(1.0% +2.0°C)
1000° to 2462°F 1°F ±(1.0% +3°F)
1000° to 1350°C 1°C ±(1.0% +2°C)
Frequency Measurement - Test lead input
Range Resolution Accuracy Overload Protection
99.99Hz 0.01Hz 0.1% +4dgts 1000V RMS
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99kHz 0.01kHz
Minimum Frequency: 0.5Hz, Sensitivity: > 10% of each AC volt range except 4V (>20%) range only
Duty Cycle
Range Accuracy Overload Protection
1.0 to 99.0% ±(0.2% per kHz +0.1% +5 dgts) 1000V RMS
Audible Continuity Measurement
Open Circuit Voltage < 0.64V Overload Protection
Threshold Approx : < 40Ω 600V RMS

Includes

  • (1) UEi DL579 Clamp Meter 400Amps
  • (1) Test Leads (ATL55)
  • (2) Temp Probe (ATT29)
  • (1) Alligator Clips (AAC3)
  • (2) Batteries (AAA)
  • (1) Zippered Pouch