UEi DL589COMBO Clamp Meter Kit with 2 ATTPC4 Temp Clamps, True-RMS, DC Amps, and Diff. Temp

Measure capacitance, voltage, circuit continuity, resistance, temperature. Check system boards and live wires.

The DL589 is an TRMS HVAC/R Clamp Meter It has functions like AC/DC voltage, AC/DC amps, AC/DC microamps, resistance, capacitance, frequency and duty cycle. CATIV rated silicone test leads, back probe leads for mini-split applications, a pair of alligator clips, two thermocouples, 2 ATTPC4, a zippered pouch, backed by a 2-Year warranty.

The ATTPC4 is designed for pipes with a diameter between 3/16 in. and 1 7/16 in. It features a 4.4 ft. cable and uses a mini-K-type connector plug.

Key Features & Benefits

  • TRMS
  • Backlit Dual Display and Worklight
  • Min/Max/Avg/Hold
  • Peak Hold
  • Auto Volts & Amp selection
  • Built-in Magnet w/ hanging strap
  • Test Lead Storage
  • Visible high-voltage alert
  • Easy access battery cover latches
  • Over-molded grip
  • Auto and Manual ranging
  • Input Jack Lock
  • Auto calibration
  • Auto Power Off
  • Low Battery Indicator
  • 2-Year limited warranty
  • 600A AC/DC
  • 1000V DC
  • 750V AC
  • 2000µA AC/DC
  • 60MΩ Resistance
  • Capacitance: 2000µF
  • Differential Temperature: -328° to 2462°F
  • Frequency/Duty Cycle
  • Audible Continuity
  • Diode Test
  • Non-Contact Voltage Detection
  • LRA Inrush
  • Low Z (impedance)

Applications

  • Measure capacitance, voltage, microamps, circuit continuity, resistance, and temperature via K-Type thermocouples. Circuits in Molex plugs, and diode malfunctions
  • Flame sensing
  • Check system boards and live wires

Specs

AC Amps Measurement - Jaw input
Range Resolution Accuracy Overload Protection
60.00A 0.01A ±2.0% +8dgts 600V RMS
600.0A 0.1A
45 to 400Hz TRMS, Minimum Current for Clamp Measurement 0.3A
DC Amps Measurement - Jaw input
Range Resolution Accuracy Overload Protection
60.00A 0.01A ±2.0% +8dgts 600V RMS
600.0A 0.1A
Minimum Current for Clamp Measurement 0.2A
AC Microamps Measurement -Test lead input
Range Resolution Accuracy Overload Protection
600.0µA 0.1µA ±1.5% +3dgts 600V RMS
2000µA 1µA
45Hz to 400Hz True RMS
DC Microamps Measurement - Test lead input
Range Resolution Accuracy Overload Protection
600.00µA 0.1µA ±1.5% +2dgts 600V RMS
2000µA 1µA
AC Volts Measurement
Range Resolution Accuracy Overload Protection
600.0mV 0.1mV ±1.0% +3dgts 1000V RMS
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
750V 1V
45Hz to 400Hz True RMS
DC Volts Measurement
Range Resolution Accuracy Overload Protection
600.0mV 0.1mV ±0.5% +4dgts 1000V RMS
6.000V 0.001V
60.00V 0.01V
600.0V 0.1V
1000V 1V ±0.8% +5dgts
Ohms Measurement
Range Resolution Accuracy Overload Protection
600.0Ω 0.1Ω ±0.8% +3dgts 600V RMS
6.000kΩ 0.001kΩ
60.00kΩ 0.01kΩ
600.0kΩ 0.1kΩ
6.000MΩ 0.001MΩ
60.00MΩ 0.01MΩ ±1.2% +3dgts
Diode Test
Range Open Circuit Voltage Test Current (Typical) Overload Protection
3.0V < 3.2V DC 0.25mA 600V RMS
Capacitance Measurement
Range Resolution Accuracy Overload Protection
10.00nF 0.01nF 3.0% +5dgts 600V RMS
100.0nF 0.1nF
1.000µF 0.001µF
10.00µF 0.01µF
100.0µF 0.1µF
2000µF 1µF
Temperature Measurement
Range Resolution Accuracy Overload Protection
-328° to 999°F 0.1°F ±(1.0% +3.6°F) 30V RMS
-200° to 999°C 0.1°C ±(1.0% +2.0°C)
1000° to 2462°F 1°F ±(1.0% +3°F)
1000° to 1350°C 1°C ±(1.0% +2°C)
Frequency Measurement - Test lead input
Range Resolution Accuracy Overload Protection
99.99Hz 0.01Hz 0.1% +3dgts 1000V RMS
999.9Hz 0.1Hz
9.999kHz 0.001kHz
99.99kHz 0.01kHz
Duty Cycle
Range Accuracy Overload Protection
1.0 to 99.0% ±(2.0% per kHz +0.1% +5 dgts) 1000V RMS
Audible Continuity Measurement
Open Circuit Voltage < 1.0V Overload Protection
Threshold Approx : < 40Ω 600V RMS

Includes

  • (1) UEi DL589 True RMS Clamp Meter
  • (2) Temp Clamp (ATTPC4)
  • (1) Silicone Test Leads (ATL58)
  • (2) Temp Probe (ATT29)
  • (1) Alligator Clips (AAC3)
  • (2) Back Probes (APB3)
  • (4) Batteries (AAA)
  • (1) Zippered Pouch
  • (1) Manual