Description
TruTech Tools Fast Recovery Custom Kit
Choose your ideal kit from multiple recovery machines and accessories
Look no further for your rapid recovery needs, TruTech has you covered. Create your ideal recovery rig from top recovery machine brands and the necessary accessories to help achieve fast, efficient recovery. For an extra BOOST of speed, supercharge your kit with the CPS MT69 Sub Cooler.
- Use the dropdown above to choose from these recovery machines:
Already own your favorite? Select “No Recovery Machine” and grab accessories to speed up your recovery! The Entry Level includes a 30lb recovery cylinder, two core tools, two yellow recovery hoses, and a filter drier with jumper hose, while the Intermediate has an extra hose, plus the MT69 Sub Cooler for dramatically improved performance up to 95% faster recovery times.
Appion G5Twin Refrigerant Recovery Machine
Select this machine using the dropdown selector above
At only 24 lbs, the industry-leading G5Twin is the smallest and lightest recovery machine capable of handling the tough demands of industrial/commercial refrigerant recovery - no job is too big for this little beast. Designed for use with all common refrigerants, including R-454B, the G5Twin pumps liquid and vapor without throttling. Featuring twin cylinders, twin condensers, a refrigerant-isolated crankcase and a turbine fan blasting over 700cfm of airflow for cool, durable, powerful operation.
Key Features & Benefits
- Compact and lightweight - Weighs only 24 lbs
- Twin Cylinders and Twin Condensers for ultra fast recovery
- Refrigerant-Isolated Crankcase eliminating bearing contamination
- Up to 4X Faster Certified Recovery Rates compared to other units within its class
- A2L Compatible all Appion HVACR products are safe to use with mildly flammable refrigerants
Permanently lubricated refrigerant isolated crankcase
Most "oil-less" recovery machines rely on the oil trapped in the refrigerant to lubricate the internal components. Because of this, the crankcase will need to be flooded with refrigerant. This is why these machines will almost always fail when pumping liquid refrigerant. The damage that the refrigerant does to the internal components far outweighs the lubrication from the oil. The G5Twin does not have this problem because the crankcase is isolated from refrigerant.
Fieldpiece MR45 Refrigerant Recovery Machine
Select this machine using the dropdown selector above
The MR45 is the first recovery machine with a smart variable speed DC motor that accelerates during vapor recovery. It has an oversize compressor that allows you to pump refrigerant more easily and quietly than ever before. Connect your hoses without lifting the pump off the ground. View status messages and pressures directly on the large backlit display.
Its lightweight size allows you to easily transport the machine to and from the job site. Turn the single rubberized control valve to route refrigerant through the MR45, and use the self-purge function to pump the last traces of refrigerant into the recovery cylinder instead of leaving it in the machine or releasing it into the environment. Class A2L compatibility for a wide range of jobs. To avoid contaminating recovered refrigerant, MR45 automatically stops at 0 psig/bar by default.
Key Features & Benefits
- Minimizes liquid slugging and maximizes vapor recovery
- Easy access ports and built in power cord storage
- Class A2L compatibility for a wide range of jobs
- Adjusts for voltage drop (runs as low as 95 VAC)
- Single dial self-purge
- Super fast DC motor (1 HP @3000 RPM)
- Extra large condenser cools faster, especially on hot days
- Lightweight only 22 lbs
- Rubberized housing protects components
- Twin cylinder compressor
- Ceramic cylinders resist abrasion
- Large backlit display with status messages
- 3 selectable auto-stop levels
NAVAC NRDD Brushless DC Recovery Unit
Select this machine using the dropdown selector above
The NRDD recovery unit offers exceptionally efficient vapor recovery due to the twin-cylinder compressor and oversized condenser with two rows of microchannel coils. The NRDD recovery unit features a Brushless DC Motor making it lightweight and much more efficient, a large backlit display, twin cylinder design with 2-row oversized condenser, oil free compressor and self-purging functionality. This DC motor technology also provides better starting performance under low voltage conditions. The NRDD recovery unit is suitable for all commonly used refrigerants making it the ideal recovery unit!
Key Features & Benefits
- Fastest in its class
- Purge function
- Prevents mixing of various refrigerants
- Oil-free compressor
- Suitable for all commonly used refrigerants
- Twin cylinder with 2-row oversized condenser
- Fastest in direct vapor for R-410A and R-22
- One-key operation
- Large backlit display with easy-to-read LCD
- Brushless DC technology
- UL-verified recovery rate
- Lightweight and efficient design
JB F6-DP Dual Piston Refrigerant Recovery Unit 115V
Select this machine using the dropdown selector above
The F6 features a 1 HP dual piston compressor for industry leading recovery rates. A micro-channel condenser provides exceptional heat exchange, allowing the F6 to put refrigerant in the tank at a lower temperature and pressure.
Key Features
- Self-purge without changing hoses
- Simple two valve operation
- Full one horsepower motor
- Powerful dual piston compressor
- Micro-channel condenser for industry leading recovery rates
- Oversized cooling fan for superior heat dissipation
- Full size protected gauges for suction and tank pressure
- Heavy-duty handle with comfortable rubber grip
- Detachable power cord
- For use with all Class III, IV and V refrigerants, including R410A
- Filter/drier included
- 3 year manufacturer warranty
Specs
| G5Twin Recovery Machine Specs | |
|---|---|
| Weight | 24 lbs |
| Power | 115 VAC, 60 Hz, 10 Amps |
| Recovery Rate |
0.55 lbs/minute vapor, 17.20 lbs/minute liquid (AHRI 740-2016 Ratings R410A) 0.46 lbs/minute vapor, 10.14 lbs/minute liquid (AHRI 740-2016 Ratings R134a) |
| Dimensions | 11.4 x 10.3 x 9.4 in. (289.6 x 261.6 x 238.8 mm) |
| MR45 Recovery Machine Specs | |
| Display: | Backlit dual LCD |
| Pressure Sensor Range: | -30” Hg to 600 psig |
| High Pressure Shut-off: | 558 psig, nominal |
| Resolution and Units: | 1 psig, 1” Hg, 0.05 bar, 0.01 Mpa, 5 Kpa, 2 cmHg |
| Final Recovery Vacuum: | 14.9” Hg |
| Compressor: | Dual cylinder reciprocating |
| DC Motor: | 1 HP (variable smart speed) |
| Power Source: | 95 to 130 VAC @ 60 Hz |
| Max Current Draw: | 12 AAC |
| Valve: | Single dual-route ball valve |
| Input Port Filtration: | 11 mm mesh screen, stainless |
| Dimensions: | 14.8” x 9.8” x 13.5” (376 mm x 250 mm x 344 mm) |
| Weight: | 22 lbs (10kg) |
| Warranty: | 1 year |
| NRDD Recovery Machine Specs | |
| Refrigerant Type |
Category III: R-12, R-134a, R-401C, R-500 Category IV: R-22, R-401A, R-401B, R-402B, R-407C, R-407D, R-408A, R-409A, R-502, R-509 Category V: R-32, R-402A, R-404A, R-407A, R-407B, R-410A, R-454B, R-507 |
| Power Supply | 115 V / 60 Hz |
| FLA | 11 A |
| Motor | 1 HP |
| Max Current Draw | 12 A |
| Compressor | Oil-less, Air-cooled, Piston style |
| Automatic Safety Shut-Off | 558 psi / 38.5 bar |
| UL Verified Recovery Rate |
Direct Vapor: R-410A 0.75 lbs/min (0.34 kg/min) R-22 0.64 lbs/min (0.29 kg/min) R-134a 0.57 lbs/min (0.26 kg/min) |
|
Direct Liquid: R-410A 14.44 lbs/min (6.55 kg/min) R-22 11.11 lbs/min (5.04 kg/min) R-134a 7.85 lbs/min (3.56 kg/min) |
|
|
Push/Pull Liquid: R-410A 18.41 lbs/min (8.35 kg/min) R-22 17.04 lbs/min (7.73 kg/min) R-134a 12.81 lbs/min (5.81 kg/min) |
|
| Dimension | 14.5" x 9.9" x 11.7" |
| Weight | 25.4 lbs |
| F6-DP Recovery Machine Specs | |
| Dimensions (L x W x H) | 11" x 19" x 16" |
| Weight | 39 lbs |
Includes
- (1) Choice of Refrigerant Recovery Machine
- (1) Choice of MT69 Molecular Transformator
- (2) 1/4" Core Tools
- (2-3) Appion MegaFlow 3/8" High Speed Recovery Hoses
- (1) CPS CRX430T Recovery Cylinder 30lb
- (1) CPS 12" Yellow Hose Whip
- (1) Liquid Line Filter Drier